[en] Copy from other part - Article inspection template (MEASURETEMPLATE) application
[en] Objective
[en] Enable users to quickly populate a measurement template by copying setup data from an existing part.
Ważne
[en] You must have access to the Article inspection template (MEASURETEMPLATE) application.
[en] The Article inspection template (MEASURETEMPLATE) must be in Status 1 - Draft.
[en] The part you want to copy from, must have a measurement template defined.
[en] Copied templates include all measurement lines, tolerances and units.
[en] Existing data in the target Product (ART) will be overwritten.
[en] The function is useful for standardizing templates across similar parts.
[en] Navigate to the source Article inspection template (MEASURETEMPLATE) via the Measure menu (MSR) application:
[en] Navigate to the Measures menu (MSR) application and list templates
[en] Option 1: RamBase menu → Production → Documentation → Measurement templates
[en] Option 2: Click the Program field and type "MSR" and press ENTER, then click the Templates radio button.
[en] Click the link in the DOCID column to open the source measurement in the Article inspection template (MEASURETEMPLATE) application.
[en] In the Article inspection template (MEASURETEMPLATE) application, click the Copy from other Part icon, found in the top right corner of the header.
[en] A dialog box will appear. Locate the source Product (ART) with the template to be copied from.
[en] Once located, either click to highlight and then press ENTER, or double click to copy the source Article inspection template (MEASURETEMPLATE) to the destination Article inspection template (MEASURETEMPLATE).